Sle 5000 ventilator user manual

Part 05 of the acutronic fabian hfo training video. Sle s software engineers are always working on new algorithms to ensure the ventilators keep up with new developments in medicine and userfeedback. Breathing systems for use with sle 4000 5000 ventilators 4609810 10mm flextube single heated wire breathing system for use with sle 4000 5000 ventilators with water trap, monitor line, autofill chamber and limb. Sle summer 2018 news other news sle6000 modularity summer 2018 welcomes the release of a new way of buying ventilators, through software modularity. The ge dash 2000 monitor is a selfcontained patient transport monitor available with an optional builtin recorder. Automatic leak compensation means that ventilator software will display the expiratory tidal volume vte inclusive of the amount that leaked out from the sides of trachea during expiration. Sle 5000 community, manuals and specifications medwrench. Those on low settings, cpap mode will be safer to manually assess. In sle 5000, there is automatic leak compensation up to 20% if on ttv mode, and 50% in ptv, simv. We have noticed that the sensibility of the sensor of flow of the babylog is bigger and quicker, the volume tidal of 0,2 ml allows to use it with smaller babies, of something more than 300 grams, its initial calibration is quicker, but the graphic interface is not very friendly, the sensor of flow is very delicate it has already been damaged.

Service manual sle 5000 ventilator stop electronic. Touchscreen neonatal ventilator with high frequency oscillation. The dash 2000 monitors sets of parameters including ecg, nibp noninvasive blood pressure, respiration, spo2, and temperature. Low cost, high performance constant flow time cycled pressure limited tcpl ventilator. The touch screen controls work beautifully and it is the closest to a plug and play ventilator i. The integrated touchscreen is angled for optimal visibility and easy to read from a distance. The ventilator needs to be intuitive and require minimum amount of training to use effectively. The patient is always the main focus and technology is the means to achieve a good outcome.

Leoni plus neonatal ventilator ventilators and care of. Especificaciones del fabricante sle 5000, sle medwow. Et leak measured inspired vol minus measured expired vol. Add singletube niv modes, hfov, vtv, spo 2, etco 2 and auto o 2 to suit your way of working. Especificaciones del fabricante sle 5000, sle por favor tenga en cuenta. The sle 5000 ventilator makes use of a heated wire sensor, which is lightweight and has a low dead space of less than 1ml. Sle 2000 easy respiration with patented system without valve. Community forums for sle relating to sle cpap service manual on medwrench. To keep up with the latest in ventilation the sle5000 has continually. Patient circuit arm for sle 40005000 ge healthcare. The user manual will from this point onwards refer to the sle4000 and sle5000 as the ventilator. Thought has been given to all aspects of the user scenarios. It does however, use and radiate radio frequency energy. The meaning of limited and cycled is different as the example.

Of course, the sle5000 still has all of the conventional ventilation modes meaning that it can be used on virtually any baby in the nicu. Going forward all new sle6000s will come with several core invasive and noninvasive modes with the option to add modules and customise the ventilator to suit customers individual requirements. The sle6000 ventilator is the gold standard infantpaediatric ventilator. The sle 5000 infant ventilator is the result of years of experience in the field of neonatal ventilation and it was designed with all this experience in mind. The sle5000 was the most powerful neonatal hfo ventilator in terms of. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. Sle2000 ventilator the sle2000 is one of the worlds most widely used infant specific ventilators. Unknown author sle, 2004 sle 2000 infant ventilator service manual. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on. On removal of air pressure it gives no air and no gas both alarm full calibration done as per the service manual. It couldnt recognize the current sensor and cant calibrate o2 sensor.

Easy to setup, easy to use, easy to train, easy to clean sle valveless technology can be interfaced. Service manual to sle5000 lungs ventilator service technicians. Even the sensormedics 3100b failed to achieve a negative pressure. Draegger babylog 8000 vs sle 5000 ventilators and care. Sle specialises in infant ventilation and as with all of our ventilators the sle6000 is optimised for the smallest of patients. Service manual sle 5000 ventilator download countless of free service manuals you find nowhere else. At sle, we believe that the user should be able to concentrate. Retain the screws and washers for reattachment of the ventilator. The mode panel is the users interface to all mode related functions. Manufacturer specifications sle 5000, sle please note.

Ahp300 electrically controlled ventilator 1720 sublette ave st. The latest software, standard on all new sle5000 and sle4000 ventilators includes. Sle 5000 the total solution for infant ventilation. Where the user manual details an operation or mode. Essential functions are never more than a couple of button pushes away. The sle 5000 infant ventilator is the result of years of experience.

Ge healthcare neonatal ventilator sle 2000 hfo neonatal. Psv with volume targeted ventilation its user friendly in slethis is. Only the sle achieved the target negative pressure of 5mbar 7. Sle 5000 neonatal ventilator, dr abid ali rizvi, nicu. Its modular design means that you can customise it to suit your patients. Neonatal ventilator with high frequency oscillation sle. The former is a general meaning but the latter means the condition to stop intake exceptionally at the extraordinary time. Bramingham business park enterprise way bedfordshire 04734 england pneupac ltd2002 lu3 4bu pn 5041117a tel. If you have any other manuals for the sle 5000 you can upload the files here. Compact design the sle6000 ventilator is housed in a single compact box, making it easier to clean and use. Ttvplus leak compensation map in hfo sle5000 battery indicator mute all alarms.

In hfo mode, the sle5000 provides oscillation with. Offering conventional ventilation as well as high performance high frequency oscillation ventilation hfov in the same machine, the sle6000 offers the complete package of neonateinfant ventilation modes in 1 system. This video is used to help guide medical, nursing and technical staff. This user manual should be read in conjunction with the user manuals for the vaporisers, anaesthesia gas delivery system, absorbers and monitoring equipment. For sale sle 5000 hfo ventilators in very good conditions. In addition to conventional ventilation for sle 2000 hfo it can provide hfo for neonatal and pediatric patients. Mechanical ventilation explained clearly ventilator. Manufacturer of ge healthcare neonatal ventilator sle 2000 hfo neonatal ventilator, sle inosys neonatal ventilator, sle 6000 neonatal ventilator and sle 5000 neonatal ventilator offered by wipro ge healthcare private limited, bengaluru, karnataka. Hi could anybody help me to get a service manual to lungs ventilator sle5000, please. Death troopers by joe schreiber,hamilton t1 ventilator service manual, toshiba e studio 255 scanning guide,conformity and conflict hamilton amadeus service manual 5.

Sle has worked hard to deliver the best user interface in the market. This manual is to be used only with model a ventilators using the following. Power supply, compressed air, oxygen supply and flow sensor duration. Louis, mo 63110 phone 3147712400 s168ahp300001 r patent pending ev. The electronic and pneumatic units of the sle5000 infant ventilator. It has a concise range of modalities for conventional ventilation. Unknown author sle, 2004 sle 2000 hfo ventilator user manual. Indeed, using conventional ventilation with higher rates and airway pressures has often led to an increased incidence of barotrauma and lung tissue damage. Sle5000 ventilator is attached to the trolley or pole by two screws with shake. The sle 5000 i have some experience with and am quite enthusiastic about it, especially the hfo modus which seems just as powerful as the sensormedics and much easier to use. Infant ventilator sle4000 patient circuit arm for sle 40005000. Indeed, using conventional ventilation with higher rates and airway pressures has often led to an increased incidence of volutrauma and lung tissue damage.

246 439 1145 53 292 1479 271 194 1431 282 1308 150 468 1517 642 251 935 1469 769 670 666 281 211 198 596 816 881 76